OPTIMISER LA COMMANDE ÉLECTRONIQUE DES VANNES D'ASPIRATION POUR GROUPES DE COMPRESSION DE GAZ

Auteurs

  • CRISTIAN NECHIFOR Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest, Romania Author
  • VALENTIN NĂVRĂPESCU Facultatea de Inginerie Electrică, Universitatea POLITEHNICA București, Romania Author https://orcid.org/0000-0002-3332-3872
  • SORIN TOMESCU Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest, Romania Author
  • CLAUDIA SĂVESCU Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest, Romania Author https://orcid.org/0000-0001-9578-1222
  • MIHAELA ROMAN Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest, Romania Author
  • RAREŞ CONŢIU Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest Author
  • ADRIAN STOICESCU Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest, Romania Author

DOI :

https://doi.org/10.59277/RRST-EE.2023.68.2.11

Mots-clés :

Contrôle électronique, Programmable logic controlle, Contrôleur proportionnel-intégratif-dérivatif, La soupape d'aspiration, Compresseur à gaz, Capteurs de surveillance, Paramètres acquis

Résumé

Dans certaines stations de compression où sont installés des ensembles compresseurs bi-vis, certains problèmes de fonctionnement ont été observés lors du redémarrage de l'ensemble après son arrêt. Le temps d'arrêt peut varier de quelques minutes à quelques jours, selon les causes de l'arrêt. Les gaz accumulés dans le tuyau d'aspiration du compresseur peuvent faire en sorte que la pression des gaz à l'entrée soit supérieure aux valeurs de pression typiques allant de la pression atmosphérique (1 bar) à 1,5 bar. Le compresseur est automatiquement arrêté via les séquences mises en œuvre dans le système de contrôle de l'automatisation si la pression à l'entrée du groupe de compression dépasse 1,5 bar, cette valeur étant la pression d'aspiration maximale que le groupe compresseur est conçu pour supporter. La solution introduit un potentiomètre pour fournir une rétroaction sur l'angle d'ouverture de la soupape d'aspiration et optimiser ainsi la commande de la soupape pour empêcher l'apparition de pressions plus élevées qui peuvent entraîner des démarrages ratés ou des arrêts d'urgence.

Biographie de l'auteur

  • CLAUDIA SĂVESCU, Romanian Research and Development Institute for Gas Turbines COMOTI, Bucharest, Romania

    Doctoral Student Eng., Scientific Researcher gr. III

    Automation and Electrical Engineering Department

Références

(1) C. Nechifor, C. Borzea, I. Vlăducă, I. Mălăel, F. Niculescu, Electrically Actuated Valves for Gas Compression Installations Located in Potentially Explosive Atmospheres, MATEC Web of Conferences, 305, p. 00027 (2020).

(2) F. Lu, J. M. Zhang, Y.M. Shen, Simulation and Research on Flow-field of Butterfly Valve in Standard Variable Head Flow Device, in 18th International Flow Measurement Conference, FLOMEKO, Lisbon, Portugal (2019).

(3) O. Kivanc, O. Ustun, G. Tosun, E. Oguz, Y. Mutlu, Design and Implementation of an Electric Actuated Valve for Precise Fluid Control, Gazi University Journal of Science, 32, 2, pp. 483-492 (2019).

(4) Q. Zhou, L. Liu, L. Jiang, Z. Xu, CMAC-PID Composite Control for the Position Control of a Fully Variable Valve System, International Journal of Automotive Technology, 24, pp. 681–691 (2023).

(5) A. Safaat, A. Noviyanto, Failure analysis of rotary screw compressor and its modifications, International Journal of Innovation in Mechanical Engineering and Advanced Materials, 3, 3 (2022).

(6) A. Bahadori, Chapter 5 - Gas Compressors, in the book: Natural Gas Processing, pp. 223–273 (2014).

(7) Y. Zhao, X.Xu, M. Qadrdan, J. Wu, Optimal operation of compressor units in gas networks to provide flexibility to power systems, Applied Energy, 290, p. 116740 (2021).

(8) S. Tomescu, V. Petrescu, A. Serban, S. Voicu, Energy Efficiency of an Oil Injected Screw Compressor Operating at Various Discharge Pressures, 10th International Conference on Energy and Environment, CIEM (2021).

(9) H.H. Patel, V.J. Lakhera, A critical review of the experimental studies related to twin screw compressors, Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 234, 1, pp. 157–170 (2019).

(10) N. Seshaiah, R.K. Sahoo, S.K. Sarangi, Theoretical and experimental studies on oil injected twin-screw air compressor when compressing different light and heavy gases, Applied Thermal Engineering, 30, 4, pp. 327–339, (2010).

(11) I.C. Mustață, L. Bacali, M. Bucur, R.M. Ciuceanu, A. Ioanid, A. Ștefan, The Evolution of Industry 4.0 and Its Potential Impact on Industrial Engineering and Management Education, Rev. Roum. Sci. Techn.– Électrotechn. et Énerg., 67, 1, pp. 73–78 (2022).

(12) S. Paker, I. Ekmekci, Electrical Hazards in Industrial Facilities and Evaluation of the Measures, Rev. Roum. Sci. Techn.– Électrotechn. et Énerg., 67, 2, pp. 133–138 (2022).

(13) P. Milosavljevic, A.G. Marchetti, A. Cortinovis, T. Faulwasser, M. Mercangöz, D. Bonvin, Real-time optimization of load sharing for gas compressors in the presence of uncertainty, Applied Energy, 272, p. 11488 (2020).

(14) R. Kurz, K. Brun, Process Control for Compression Systems, Journal of Engineering for Gas Turbines and Power-transactions of the ASME (2017).

(15) R.S. Gesser, R. Sartori, T.P. Damo, C.M. Vettorazzo, L.B. Becker, D.M. Lima, M.L. de Lima, L.D. Ribeiro, M.C.M. M. Campos, J.E. Normey-Rico, Advanced control applied to a gas compression system of an offshore platform: From modeling to related system infrastructure, Journal of Petroleum Science and Engineering, 208, p. 109428 (2022).

(16) ***Introduction to Butterfly Valves, The Process Piping (2020).

(17) C. Nechifor, C. Borzea, A. Stoicescu, D. Lale, M. Vasile, Modular automation cabinet for proactive monitoring in ATEX Zone 2, MATEC Web of Conferences, 354, p. 00044 (2022).

(18) S.A. Babichev, P.A. Zakharov, O.V. Kryukov, Automated monitoring system for drive motors of gas-compressor units, Automation and Remote Control, 72, 1, pp. 175–180 (2011).

(19) A. Benachour, E.M. Berkouk, M.O. Mahmoudi, A new direct torque control of induction machine fed by indirect matrix converter, Rev. Roum. Sci. Techn.– Électrotechn. et Énerg., 62, 1, pp. 25–30 (2017).

(20) R. Arun, R. Muniraj, M.S.W. Iruthayarajan, Performance analysis of proportional integral derivative controller with delayed external reset and proportional integral derivative controller for time delay process, Rev. Roum. Sci. Techn. – Électrotechn. et Énerg., 66, 4, pp. 267–273 (2021).

(21) Q.K. Nguyen, K.H. Jung, G.N. Lee, S.B. Park, J.M. Kim, S.B. Suh, J.Y. Lee, Experimental study on pressure characteristics and flow coefficient of butterfly valve, International Journal of Naval Architecture and Ocean Engineering, 15, p. 100495 (2023).

Téléchargements

Publiée

2023-07-03

Numéro

Rubrique

Électrotechnique et électroénergétique | Electrical and Power Engineering

Comment citer

OPTIMISER LA COMMANDE ÉLECTRONIQUE DES VANNES D’ASPIRATION POUR GROUPES DE COMPRESSION DE GAZ. (2023). REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE, 68(2), 182-187. https://doi.org/10.59277/RRST-EE.2023.68.2.11