ANALYSE MAGNÉTIQUE DES DISPOSITIFS À CHAMP MAGNÉTIQUE ROTATIF UTILISÉS POUR LES ÉTUDES SUR LES CELLULES SANGUINES

Auteurs

  • VALENTIN IONIŢĂ Faculty of Electric Engineering, National University of Science and Technology POLITEHNICA Bucharest, Romania. Author
  • MIHAI REBICAN Faculty of Electric Engineering, National University of Science and Technology POLITEHNICA Bucharest, Romania. Author
  • LUCIAN PETRESCU Faculty of Electric Engineering, National University of Science and Technology POLITEHNICA Bucharest, Romania. Author

DOI :

https://doi.org/10.59277/RRST-EE.2026.1.27

Mots-clés :

Informatique en génie électrique, Analyse magnétique, Noyaux magnétiques, Champ magnétique tournant, Cellules biologiques

Résumé

L'étude des effets au niveau moléculaire dans les cellules sanguines du champ magnétique variable nécessite la conception de dispositifs magnétiques appropriés. Dans cet article, quatre configurations immobiles sont analysées : les bobines de Helmholtz, les bobines de Gramme, un électroaimant à 4 pôles et un électroaimant à 6 pôles. Ces dispositifs peuvent créer une densité de flux magnétique rotatif, intense (jusqu'à plusieurs centaines de mT), à haute fréquence (jusqu'à 1 MHz) et avec un degré approprié d'hétérogénéité (maximum 5 %) dans la zone du bioréacteur de 1 cm de diamètre. Le champ rotatif est créé en alimentant les bobines composantes avec des courants ayant des phases décalées. L'analyse numérique comparative originale réalisée à l'aide du logiciel COMSOL a mis en évidence l'effet de la géométrie du dispositif, du type de noyau et de conducteur, en corrélation avec la fréquence de fonctionnement, sur le niveau de densité du flux magnétique dans les cellules sanguines. Des résultats originaux et utiles ont été tirés de l'analyse de l'homogénéité du champ magnétique dans le domaine du bioréacteur.

Références

(1) M. Tota, L. Jonderko, J. Witek, V. Novickij, J. Kulbacka, Cellular and molecular effects of magnetic fields, International Journal of Molecular Sciences, 25, 16, 8973 (2024).

(2) S. Prawanta, P. Sunwong, B. Boonwanna, V. Sooksrimuang, A. Kwankasem, S. Pongampai, P. Sudmuang, P. Klysubun, Design and construction of sextupole magnet prototype for Siam Photon Source II, 10th International Particle Accelerator Conference (IPAC 2019), Melbourne, Australia, pp. 4285–4297 (2019).

(3) A. Skumiel, J. Musiał, The use of Gramme coils in a 2-phase system for generation of a high frequency rotating magnetic field, Journal of Magnetism and Magnetic Materials, 564, 170198 (2022).

(4) N. Hallali, T. Rocacher, C. Crouzet, J. Béard, T. Douard, A. Khalfaoui, Low-frequency rotating and alternating magnetic field generators for biological applications: design details of home-made setups, Journal of Magnetism and Magnetic Materials, 564, 170093 (2022).

(5) A. Skumiel, Generation of a rotating high-frequency magnetic field designed for use in magnetic hyperthermia, Journal of Magnetism and Magnetic Materials, 553, 169294 (2022).

(6) R.M. Wojciechowski, A. Skumiel, M. Kurzawa, A. Demenko, Design, application and investigation of the system for generation of fast changing, rotating magnetic field causing hyperthermic effect in magnetic liquids, Measurement, 194, 111020 (2022).

(7) H. Ding, Z. Zhao, C. Jiang, Y. Xu, T. Ding, X. Fang, T. Ren, L. Li, Y. Pan, T. Peng, Construction and test of three-coil magnet power supply system for a high-pulsed magnetic field, IEEE Transactions on Applied Superconductivity, 28, 3, 5000606 (2018).

(8) J.R. Michel, S.B. Betts, J.D. Lucero, A. Bhardwaj, L.N. Nguyen, D.N. Nguyen, Design and construction of the new 85 T duplex magnet at NHMFL–Los Alamos, IEEE Transactions on Applied Superconductivity, 34, 5, 4900305 (2024).

(9) Y. Song, Z. Cheng, X. Jiang, J. Li, L. Li, Q. Wang, Design, test, and shimming of a 1.5 T head-only MRI superconducting magnet, IEEE Transactions on Applied Superconductivity, 35, 6, 3800505 (2025).

(10) I. Dobrin, D. Enache, G. Dumitru, M. Gutu, S. Zamfir, R. Pintea, Curved dipolar electromagnet, numerical modeling and design, Rev. Roum. Sci. Techn. – Électrotechn. et Énerg., 67, 4, pp. 409–415 (2022).

(11) Y. Lu, Y. Yang, M. Zhang, R. Wang, L. Jiang, B. Qin, Improved square-coil configurations for homogeneous magnetic field generation, IEEE Transactions on Industrial Electronics, 69, 6, pp. 6350–6360 (2022).

(12) Z. Ding, Z. Huang, M. Pang, G. Bai, Q. Wang, B. Han, Optimized design of uniform-field coils system with a large uniform region by particle swarm optimization algorithm, Measurement, 234, 114614 (2024).

(13) X. Zhu, C. Liu, H. Su, Y. Miao, H. Cheng, Design of improved four-coil structure with high uniformity and effective coverage rate, Heliyon, 9, 4, e15193 (2023).

(14) O. Sucre, S. Glöggler, Optimization method based on zonal harmonics for axially symmetric magnets, IEEE Transactions on Magnetics, 61, 2, 5100109 (2025).

(15) T.J. Havens, T. Duby, J. Huang, VRMS homogeneity definition: a proposal, Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2002).

(16) V. Zablotskii, T. Polyakova, A. Dejneka, Effects of high magnetic fields on the diffusion of biologically active molecules, Cells, 11, 1, 81 (2021).

(17) C.M. Ciocazeanu, D.E. Nitescu, M. Morega, Useful assumption for simplified numerical analysis of transcranial magnetic stimulation, Rev. Roum. Sci. Techn. – Électrotechn. et Énerg., 70, 3, pp. 427–432 (2025).

(18) L. Petrescu, V. Ionita, M. Rebican, M.C. Petrescu, Optimization of quadrupole core for homogenous magnetic field using non-oriented silicon-iron materials, U.P.B. Scientific Bulletin, Series C, 87, 4 (2025).

(19) ***COMSOL, COMSOL Multiphysics® modeling software.

(20) A. Bermudez, D. Gomez, P. Salgado, Eddy-current losses in laminated cores and the computation of an equivalent conductivity, IEEE Transactions on Magnetics, 44, 12, pp. 4730–4738 (2008).

(21) F. Saftoiu, Y. Veli, A.M. Morega, Electropermeabilization for organic material – numerical modeling, Rev. Roum. Sci. Techn. – Électrotechn. et Énerg., 70, 4, pp. 603–608 (2025).

Téléchargements

Publiée

2026-03-08

Numéro

Rubrique

Génie biomédicale

Comment citer

ANALYSE MAGNÉTIQUE DES DISPOSITIFS À CHAMP MAGNÉTIQUE ROTATIF UTILISÉS POUR LES ÉTUDES SUR LES CELLULES SANGUINES. (2026). REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE, 71(1), 163-168. https://doi.org/10.59277/RRST-EE.2026.1.27