Abstract

 The paper presents the functioning regimes of a 132 kW asynchronous three-phase machine, used for the expander-generator system in a compressed air energy storage facility. The installation consists of a 110 kW twin-screw electro-compressor, which supplies pressurized air up to ~16 bar into a 50 m3 storage vessel. The compressed air is afterward released from the reservoir into the expander’s inlet, spinning its shaft. When the expander’s shaft spins the electric machine over its synchronous speed, this one enters in generator mode, supplying electric power into the grid. Two power analyzers installed on the automation control cabinet monitor the generated/absorbed power and the power supplied/consumed by the system from the grid. Using the data acquired by means of PLC during commissioning tests, we plotted the power curves, differential pressure, and significant temperatures, as well as the electric machine’s speed. 

References

(1) R. Kumawat, S. Chourasiya, S. Agrawal and D. Paliwalia, "Self excited induction generator: A review", International Advanced Research Journal in Science, Engineering and Technology (IARJSET), vol. 2, Special Issue 1, 2015.

(2) Y. Zou, "Induction Generator in Wind Power Systems", Induction Motors - Applications, Control and Fault Diagnostics, 2015.

(3) D. Borkowski, "Voltage and frequency control of a stand-alone induction generator using sVPWM converter in a small reservoir hydropower plant", Technical Transactions Electronical Engineering, Issue 3E-2016, 2016.

(4) R. Saket and L. Varshney, "Self Excited Induction Generator and Municipal Waste Water-Based Micro Hydro Power Generation System", International Journal of Engineering and Technology, vol. 4, no. 3, pp. 282-287, 2012.

(5) J. Chapallaz, J. Dos Ghali, P. Eichenberger, and G. Fischer, "The Concept of Induction Motors Used as Generators", Manual on Induction Motors Used as Generators, pp. 3-14, 1992.

(6) C. Borzea, A. Săvescu, C. Hărăguță, A. Găzdac and R. Nedelcu, "Automation and Electrical Actuation of a Compressed Air Energy Storage Installation", Actualităţi şi Perspective în Domeniul Maşinilor Electrice (Electric Machines, Materials and Drives - Present and Trends)", vol. 1, no. 1, pp. 1-12, 2020.

(7) C. Borzea, I. Vlăducă, D. Ionescu, V. Petrescu, F. Niculescu, C. Nechifor, G. Vătășelu and M. Hanek "Compressed Air Energy Storage Installation for Renewable Energy Generation", E3S Web of Conferences, vol. 112, p. 02010, 2019.

(8) I. Vlăducă, C. Borzea, D. Ionescu, A. Ţăranu, R. Ciobanu, V. Ringheanu and R. Nedelcu. "Compressed air energy storage facility with water tank for thermal recovery", E3S Web of Conferences, vol. 180, p. 02002, 2020.

(9) COMOTI - Institutul National de Cercetare Dezvoltare Turbomotoare, "Microcentrală cogenerativă inovativă, de înalt nivel tehnologic, cu putere electrică instalată de 200 kW (MCT200)", comoti.ro, 2017, http://www.comoti.ro/ro/Proiect_MCT200.htm?pag=3.

(10) W. Freitas, J. Vieira, A. Morelato, L. DaSilva, V. da Costa, and F. Lemos, "Comparative Analysis Between Synchronous and Induction Machines for Distributed Generation Applications", IEEE Transactions on Power Systems, vol. 21, no. 1, pp. 301-311, 2006.

V. Dahiya, L. G, "Comparative Study of Doubly Fed Induction Generator and Permanent Magnet Synchronous Generator in Wind Energy Conversion System", International Journal of Electrical Engineering & Technology, vol. 10, Special Issue 3, 2019.

(12) M. Ignat and I. Haraguta, "The asynchronous high-speed motor for an axial compressor application", International Aegean Conference on Electrical Machines and Power Electronics and Electromotion, Joint Conference, 2011.

(13) M. Simões, "Modeling a self-excited induction generator", Report, Colorado School of Mines. Arthur Lakes Library, 2019. [Online].

(14) UMEB, MOTOARE ASINCRONE TRIFAZATE, pdf, Uzina de Mașini Electrice București, n.d., http://www.umeb.ro/upload/files/carti_tehnice/catalog_motoare_romana.pdf.

(15) D. Bagarty and D. Kastha, "Reactive power allocation for loss minimization in a stand-alone variable speed constant frequency double output induction generator", IET Power Electronics, vol. 6, no. 5, pp. 851-861, 2013.

Downloads